U1
Abnormal High Pressure (63H Tripped)
Description
The outdoor unit's high-pressure switch (63H) has tripped due to excessive refrigerant pressure.
Appliance Error Codes Details
Additional Troubleshooting
1. Turn off the unit
2. Check that indoor and outdoor units have adequate airflow and no short-cycling of air
3. Clean the outdoor heat exchanger and air filters if dirty
4. Contact service to check the pressure switch and refrigerant charge
2. Check that indoor and outdoor units have adequate airflow and no short-cycling of air
3. Clean the outdoor heat exchanger and air filters if dirty
4. Contact service to check the pressure switch and refrigerant charge